Can a Leaf Wetness Sensor be a Rain Detector?

The PHYTOS 31 Leaf Wetness Sensor was designed to measure the presence and duration of water on leaf surfaces. However, Dr. Bruce Bugbee, professor of Crop Physiology at Utah State University, noticed that his leaf wetness sensor revealed interesting phenomena associated with some precipitation events. Here is what he observed on a recent day at the USU Environmental Observatory in Logan, Utah

Water droplets on a leaf

It is possible to have a day with numerous 0.1 mm increments of rain, followed by some evaporation, in which a rain gauge would not record any rain during the day.

“Recent data from our weather station provided two examples of the offset in measurement associated with tipping bucket rain gauges. It started raining on campus last night at exactly 20:00 hours, as indicated by the response of the leaf wetness sensor (Figure 1). The first 0.1 mm tip of the rain gauge occurred about 25 minutes later (Figure 2). The resolution for most high-quality tipping bucket rain gauges is listed as 0.1 mm, but this is not the resolution for the first 0.1 mm of rain.

Read more

Download the “Researcher’s complete guide to soil moisture”—>

Stop Hiding Behind a Shield

Get better air temperature accuracy with this new method

ATMOS 41 weather station standing in a field

Accurate air temperature is crucial for microclimate monitoring

The accuracy of air temperature measurement in microclimate monitoring is crucial because the quality of so many other measurements depend on it. But accurate air temperature is more complicated than it looks, and higher accuracy costs money. Most people know if you expose an air temperature sensor to the sun, the resulting radiative heating will introduce large errors. So how can the economical ATMOS 41’s new, non-radiation-shielded air temperature sensor technology be more accurate than typical radiation-shielded sensors?

We performed a series of tests to see how the ATMOS 41’s air temperature measurement compared to other sensors, and the results were surprising, even to us. Learn the results of our experiments and the new science behind the extraordinary accuracy of the ATMOS 41’s breakthrough air temperature sensor technology.

In this brief 30-minute webinar, find out:

  • Why you should care about air temperature accuracy
  • Where errors in air temperature measurement originate
  • The first principles energy balance equation and why it matters
  • Results of experiments comparing shielded sensor accuracy against the ATMOS 41 weather station
  • The science behind the ATMOS 41 and why its unshielded measurement actually works

Watch the webinar

See weather sensor performance data for the ATMOS 41 weather station.

Explore which weather station is right for you.

Download the “Researcher’s complete guide to soil moisture”—>